Flow Cytometry Core

The Flow Cytometry Core Facility offers state-of-the-art flow cytometry analysis and cell sorting for Stark Neurosciences Research Institute-affiliated researchers. Several thousand cells can be analyzed and processed using the equipment in a minute.

What can the Core do for you?

  • Help design panels and optimize experimental plans.
  • Provide consultation for data analysis.
  • Prepare and maintain the equipment for users performing FACS or flow cytometry.
  • Provides sorting and cleaning chips required for sorting.
  • Provide calibration beads for both instruments.
  • Calibrate lasers and set up the BDLSR Fortessa-X20 prior to experiments.
  • Regular courses to improve your flow cytometry.

Core Services

  • 18-parameter (16 fluorescence, FSC, SSC) cell analyzer
  • The X-20 accepts FALCON brand polystyrene 5mL FACS tubes, with an optional 96 wellplate sampler (HTS)
  • Exciter Lasers: 405, 488, 561, 638
  • Detectors
    • 405 detectors: 450/50; 525/50; 610/20; 670/30; 710/50; 780/60
    • 488 detectors: 530/30; 710/50
    • 561 detectors: 586/15; 610/20; 670/30; 710/50; 780/60
    • 638 detectors: 670/30; 730/45; 780/60

  • 14-parameter (12 fluorescence, FSC, SSC) cell sorting flow cytometer housed in a biosafety cabinet. It can also be used as a non-sorting cell analyzer.
    • 2-way sorting into 15mL conicals
    • 4-way sorting into 5mL FACS tubes
    • Well plate sorting into 6/12/24/48/96/384 well plates
  • Sorting chips are a required consumable for running the Sony, and cost $40/each. 100 micron chips (general-purpose sorting) and 130 micron chips (for large and fragile cells) are available. If you need 130 micron chips, please reach out ahead of time as these are infrequently used.  
  • The MA900 has two sets of colinear exciter lasers, pairing 405+647 and 488+561. This requires careful consideration when designing flow panels for use on the MA900.
  • Detectors
    • 488+561 detectors: 525/50; 585/30; 617/30; 695/50; 785/60
    • 405+638 detectors: 450/50; 525/50; 585/30; 617/30; 665/30; 720/60; 785/60

  • 10-parameter (8 fluorescence, FSC, SSC) cell analyzer.
  • The MACSQuant 10 is a user-friendly, highly automated instrument with the ability to self-clean and shutdown.
  • The MACSQuant will be slower, less sensitive, and less precise than the Sony MA900 or LSRFortessa X-20.
  • The MACSQuant can run96-well plates, 5mL FACS tubes, 15 and 50mL conical tubes.
  • Exciter lasers: 405, 488, 638nm
  • Detectors:
    • 405 detectors: 450/50; 525/50
    • 488 detectors: 525/50; 585/40; 655-730; 750LP
    • 635 detectors: 655-730; 750LP
    • Overnight, unsupervised runs are available at a flat fee.

  • gentleMACS Octo tissue dissociator
  • A limited set of consumables and reagents are available for new users curious about the platform. Please inquire.
  • Panel Design or Data Analysis Consultation
  • Use of Flowjo (dongle) or OMIQ data analysis software (cloud login)

core leadership

Request Services

In need of services at the Flow Cytometry Core?  Contact Riley Hannan for consultation and equipment access or request services below.
70936-Hannan, Riley

Riley T. Hannan, PhD

Assistant Research Professor of Neurology

Core Co-Director

Read Bio

68202-Merchak, Andrea

Andrea R. Merchak, PhD

Assistant Research Professor of Neurology

Core Co-Director

Read Bio

headshot of Jeff Recchia-Rife

Jeff Recchia-Rife

Core Lab Manager

Email

a headshot of Tammy Fajfer

Tammy Fajfer

Research Centers/Cores Finance Manager

Email